[1]柯嘉 朱云峰① 李倩 胡磊① 马芙蓉**.不同钻速下电钻钻孔骨质产热的比较[J].中国微创外科杂志,2015,15(11):852-854.
 Ke Jia*,Zhu Yunfeng,Li Qian*,et al.Comparison of Heat Generation During Bone Drilling Using Different Drill Speeds[J].Chinese Journal of Minimally Invasive Surgery,2015,15(11):852-854.
点击复制

不同钻速下电钻钻孔骨质产热的比较()
分享到:

《中国微创外科杂志》[ISSN:1009-6604/CN:11-4526/R]

卷:
15
期数:
2015年11期
页码:
852-854
栏目:
短篇报道
出版日期:
2015-11-20

文章信息/Info

Title:
Comparison of Heat Generation During Bone Drilling Using Different Drill Speeds
作者:
柯嘉 朱云峰① 李倩 胡磊① 马芙蓉**
(北京大学第三医院耳鼻咽喉头颈外科,北京100191)
Author(s):
Ke Jia* Zhu Yunfeng Li Qian* et al.
*Department of Otorhinolarygology Head and Neck Surgery, Peking University Third Hospital, Beijing 100191, China
关键词:
钻孔产热钻速温度
Keywords:
DrillHeat generationDrill speedTemperature
分类号:
R608
文献标志码:
D
摘要:
目的比较采用不同钻速进行电钻钻孔操作时,骨质局部温度的变化,获取在微创隧道人工耳蜗植入手术中电钻钻孔操作的安全参数。方法采用外形近似的新鲜猪肋骨块,在两块骨块的截面依次安放3枚热敏电阻(Pt100)并固定,分别于皮质骨表面,距离横截面1.5 mm处进行钻孔操作。按照钻速由低至高,人为分为100、1250、7000、10 000、20 000、30 000和40 000 r/min,每个钻速重复实验6次,记录钻孔时的温度变化。比较不同钻速钻孔时骨质升温的差异。结果采用100 r/min钻孔时,钻孔局部骨质的平均升温(3.81±1.47)℃,采用1250 r/min钻孔时,骨质平均升温(11.57±4.32)℃,两者间差异无显著性(P=0.130);在钻速为7000 r/min钻孔时,骨质升温(18.01±3.62)℃,与10 000 r/min钻速组的(43.09±1005)℃比较,两者差异有统计学意义(P=0.000);当转速高于10 000 r/min时,提高转速后局部骨质升温的变化无显著性差异。结论在本研究条件下,使用低钻速100 r/min和1250 r/min进行钻孔操作时,骨质局部升温较小,当钻孔局部要求的温度不能过高时,应选择低钻速进行操作。
Abstract:
ObjectiveTo compare changes in bone temperature during the drilling using different drill speeds and to get the safe parameters of drilling operation in minimal invasive cochlear implant.MethodsFresh pig ribs bone samples with similar shape were used in this study. Three thermistors (Pt100) were fixed in the transverse section of the bones. There were seven drilling speeds groups which included 100, 1250, 7000, 10 000, 20 000, 30 000 and 40 000 r/min. Drilling were used to create holes at the location 15 mm from the thermistors with different speeds. Changes in temperature were recorded. ResultsThe mean temperature raise when drilling in 100 r/min was (3.81±1.47) ℃ and in 1250 r/min was (11.57±4.32) ℃, without statistical difference (P=0130). The mean temperature raise when drilling in 7000 r/min was (18.01±3.62) ℃ and in 10 000 r/min was (43.09±10.05) ℃, with statistically difference (P=0.000). There were no significant differences in temperature raise when the drilling speeds were higher than 10 000 r/min. ConclusionsWithin the limitations of this study, drilling bones in 100 r/min and 1250 r/min generates less heat. When the local temperature be limited, low speed drilling should be used in drilling the bone.

参考文献/References:

[1]Augustin G,Zigman T,Davila S,et al.Cortical bone drilling and thermal osteonecrosis.Clin Biomech (Bristol, Avon),2012,27(4):313-325.
[2]Kim SJ,Yoo J,Kim YS,et al.Temperature change in pig rib bone during implant site preparation by low-speed drilling.J Appl Oral Sci,2010,18(5):522-527.
[3]Arnold A,Caversaccio MD,Mudry A.Surgery for the bone-anchored hearing aid.Adv Otorhinolaryngol,2011,71:47-55.
[4]Labadie RF,Noble JH,Dawant BM,et al.Clinical validation of percutaneous cochlear implant surgery:initial report.Laryngoscope,2008,118(6):1031-1039.
[5]Balachandran R,Mitchell JE,Blachon G,et al.Percutaneous cochlear implant drilling via customized frames:an in vitro study.Otolaryngol Head Neck Surg,2010,142(3):421-426.
[6]Bell B,Stieger C,Gerber N,et al.A self-developed and constructed robot for minimally invasive cochlear implantation.Acta Otolaryngol,2012,132(4):355-360.
[7]Eriksson A,Albrektsson T,Grane B,et al.Thermal injury to bone.A vital-microscopic description of heat effects.Int J Oral Surg,1982,11(2):115-121.
[8]Eriksson RA,Adell R.Temperatures during drilling for the placement of implants using the osseointegration technique.J Oral Maxillofac Surg,1986,44(1):4-7.
[9]Shaw ML,Kelley B,Camarata P,et al.Collateral damage: heat transfer as a possible mechanism of optic nerve injury during neurosurgical intervention.Ophthal Plast Reconstr Surg,2012,28(5):328-330.
[10]Call WH.Thermal injury from mastoid bone burs.Ann Otol,1978,87:43-49.
[11]魏新邦.乳突手术时的电钻热损伤.国外医学·耳鼻咽喉科学分册,1981,(5):380-381.
[12]Keim RJ,Erdreich J,Love TJ.Thermal hazards in mastoid surgery:an evaluation of instruments and irrigation techniques.Otolaryngol Head Neck Surg,1979,87(4):472-478.
[13]Aslan A,Vatansever HS,Aslan GG,et al.Effect of thermal energy produced by drilling on the facial nerve:histopathologic evaluation in guinea pigs.J Laryngol Otol,2005,119(8):600-605.
[14]Sumer M,Misir AF,Telcioglu NT,et al.Comparison of heat generation during implant drilling using stainless steel and ceramic drills.J Oral Maxillofac Surg,2011,69(5):1350-1354.
[15]Bertollo N,Milne HR,Ellis LP,et al.A comparison of the thermal properties of 2- and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model.Clin Biomech (Bristol, Avon),2010,25(6):613-617.
[16]Davidson SR,James DF.Drilling in bone:modeling heat generation and temperature distribution.J Biomech Eng,2003,125(3):305-314.
[17]Benington IC,Biagioni PA,Briggs J,et al.Thermal changes observed at implant sites during internal and external irrigation.Clin Oral Implants Res,2002,13(3):293-297.
[18]柯嘉,马芙蓉,朱云峰,等.耳科手术电钻钻孔对骨质产热影响的实验研究.中国耳鼻咽喉头颈外科,2013,20(9):475-479.

备注/Memo

备注/Memo:
基金项目:首都卫生发展科研专项项目(2011-4023-03);2011北京大学第三医院临床学科重点项目**通讯作者,E-mail:furongma@126.com①(北京航空航天大学机器人研究所,北京100191)
更新日期/Last Update: 2016-02-03