[1]骆鹏飞 穆夏黎 焦大海** 张培新.甲状腺结节细针穿刺中使用空芯针或带芯针的标本满意率的比较[J].中国微创外科杂志,2021,01(11):1016-1019.
 Luo Pengfei,Mu Xiali,Jiao Dahai,et al.A Comparison of Satisfaction Rate of Samples Between Hollow Needle and Stylet Needle in Fineneedle Aspiration of Thyroid Nodules[J].Chinese Journal of Minimally Invasive Surgery,2021,01(11):1016-1019.
点击复制

甲状腺结节细针穿刺中使用空芯针或带芯针的标本满意率的比较()
分享到:

《中国微创外科杂志》[ISSN:1009-6604/CN:11-4526/R]

卷:
01
期数:
2021年11期
页码:
1016-1019
栏目:
临床研究
出版日期:
2021-11-25

文章信息/Info

Title:
A Comparison of Satisfaction Rate of Samples Between Hollow Needle and Stylet Needle in Fineneedle Aspiration of Thyroid Nodules
作者:
骆鹏飞 穆夏黎 焦大海** 张培新
(安徽医科大学附属阜阳人民医院阜阳市人民医院甲状腺乳腺外科,阜阳236000)
Author(s):
Luo Pengfei Mu Xiali Jiao Dahai et al.
Department of Thyroid and Breast Surgery, Fuyang People’s Hospital of Anhui Medical University, Fuyang People’s Hospital, Fuyang 236000, China
关键词:
甲状腺结节活组织检查细针标本满意率
Keywords:
Thyroid noduleBiopsyFineneedleSample satisfaction rate
文献标志码:
A
摘要:
目的探讨使用空芯针或带芯针对甲状腺结节细针穿刺细胞学检查(fineneedle aspiration cytology,FNAC)标本满意率的影响。方法纳入2019年8月~2020年4月甲状腺结节FNAC患者147例,随意分成2组。组一74例,先使用空芯针(5 ml注射器25G针头),后使用带芯针(25G多用途千叶针);组二73例,先使用带芯针,后使用空芯针。2组一般资料及结节彩超特征比较差异无统计学意义。空芯针和带芯针各穿刺涂片1张,比较带芯针和空芯针标本满意率。结果空芯针的标本满意率明显高于带芯针[83.7%(123/147) vs. 72.1%(106/147), χ2=5.708,P=0.017]。结论对于经验丰富的穿刺操作者,使用带芯针无法提升标本满意率。
Abstract:
ObjectiveTo investigate the influence of two different needles on satisfaction rate of samples in fineneedle aspiration cytology (FNAC) of thyroid nodules. Methods A total of 147 patients with thyroid nodules who were referred for FNAC between August 2019 and April 2020 were included and divided into 2 groups. In the group 1, 74 patients were treated with hollow needle (5 ml syringe, 25 G needle) firstly and then with stylet needle (25 G multipurpose chiba needle). In the group 2, 73 patients were treated with stylet needle firstly and then with hollow needle. No significant differences in general conditions and color doppler ultrasonography of nodules were found between the two groups. One smear was taken for each of the hollow needle and stylet needle, and the satisfaction rate of samples was compared.ResultsThe sample satisfaction rate of hollow needle was significantly higher than that of stylet needle [83.7% (123/147) vs. 72.1% (106/147), χ2=5.708, P=0.017].ConclusionFor experienced surgeons, the use of stylet needle does not increase the rate of satisfactory specimen.

参考文献/References:

[1]骆鹏飞,穆夏黎,焦大海,等.针径大小和穿刺手法对甲状腺结节细针穿刺细胞学检查标本满意率的影响.中国耳鼻咽喉颅底外科杂志,2021,27(1):16-20.
[2]谭石,姚宏伟,贾建文,等.超声引导下细针穿刺在甲状腺小结节诊断中的应用.中国微创外科杂志,2014,14(12):1065-1067.
[3]Gill AS,Amdur R,Joshi AS.Importance of FNA technique for decreasing nondiagnostic rates in thyroid nodules.Head Neck Pathol,2018,12(2):160-165.
[4]程颢,杨高怡,张超.超声引导下甲状腺结节细针穿刺术的个人学习曲线初步研究.中华医学超声杂志(电子版),2020,17(2):153-158.
[5]袁华芳,蒋天安,赵齐羽,等.超声引导下细针穿刺细胞学检查对长径≤5 mm甲状腺微小癌的诊断价值.中国微创外科杂志,2016,16(2):151-153.
[6]Cappelli C,Tironi A,Pirola I,et al.Spinal needle improves diagnostic cytological specimens of thyroid nodules.J Endocrinol Invest,2008,31(1):25-28.
[7]Cappelli C,Pirola I,Gandossi E,et al.Fineneedle aspiration cytology of thyroid nodule:does the needle matter?South Med J,2009,102(5):498-501.
[8]Abe Y,Kawakami H,Oba K,et al.Effect of a stylet on a histological specimen in EUSguided fineneedle tissue acquisition by using 22-gauge needles:a multicenter,prospective,randomized,controlled trial.Gastrointest Endosc,2015,82(5):837-844.e1.
[9]Xu Y,Lin J,Jin Y,et al.Is endobronchial ultrasoundguided transbronchial needle aspiration with a stylet necessary for lymph node screening in lung cancer patients?Braz J Med Biol Res,2017,50(10):e6372.
[10]Sahai AV,Paquin SC,Gariépy G.A prospective comparison of endoscopic ultrasoundguided fine needle aspiration results obtained in the same lesion,with and without the needle stylet.Endoscopy,2010,42(11):900-903.
[11]中华人民共和国国家卫生健康委员会.甲状腺癌诊疗规范(2018年版).中华普通外科学文献(电子版),2019,13(1):1-15.
[12]Cibas ES,Ali SZ.The 2017 Bethesda system for reporting thyroid cytopathology.Thyroid,2017,27(11):1341-1346.
[13]de Meer SG,Schreinemakers JM,Zelissen PM,et al.Fineneedle aspiration of thyroid tumors:identifying factors associated with adequacy rate in a large academic center in the Netherlands.Diagn Cytopathol,2012,40(Suppl 1):E21-E26.
[14]骆鹏飞,穆夏黎,焦大海,等.甲状腺结节细针穿刺细胞学检查标本充分性的影响因素.中华医学杂志,2020,100(24):1913-1916.
[15]Jack GA,Sternberg SB,Aronson MD,et al.Nondiagnostic fineneedle aspiration biopsy of thyroid nodules:outcomes and determinants.Thyroid,2020,30(7):992-998.
[16]Lyu YJ,Shen F,Yan Y,et al. Ultrasoundguided fineneedle aspiration biopsy of thyroid nodules <10 mm in the maximum diameter:does size matter?Cancer Manag Res,2019,7(11):1231-1236.
[17]赵美丽,邵国强.影响细针穿刺细胞学检测甲状腺癌准确度的超声特征分析.中国超声医学杂志,2021,37(3):241-244.
[18]阳仔怡.超声引导下细针穿刺甲状腺结节Bethesda I类标本的影响因素.临床与病理杂志,2021,41(6):1469-1475.

备注/Memo

备注/Memo:
基金项目:阜阳市自筹经费科技计划项目(FK202081015)**通讯作者,Email:dahaijiao1008@163.com
更新日期/Last Update: 2022-02-10