[1]曹贵华** 刘亮程 杜建平 黄贵闽 李伟 李强.3D打印激光工作鞘在绿激光前列腺汽化术中的安全性和有效性[J].中国微创外科杂志,2020,01(10):883-886.
 Cao Guihua,Liu Liangcheng,Du Jianping,et al.Safety and Efficacy of 3Dprinted Laser Working Shealth Applying in Photoselective Vaporization of the Prostate[J].Chinese Journal of Minimally Invasive Surgery,2020,01(10):883-886.
点击复制

3D打印激光工作鞘在绿激光前列腺汽化术中的安全性和有效性()
分享到:

《中国微创外科杂志》[ISSN:1009-6604/CN:11-4526/R]

卷:
01
期数:
2020年10期
页码:
883-886
栏目:
临床研究
出版日期:
2020-10-25

文章信息/Info

Title:
Safety and Efficacy of 3Dprinted Laser Working Shealth Applying in Photoselective Vaporization of the Prostate
作者:
曹贵华** 刘亮程 杜建平 黄贵闽 李伟 李强
(乐山市人民医院泌尿外科,乐山614000)
Author(s):
Cao Guihua Liu Liangcheng Du Jianping et al.
Department of Urology, People’s Hospital of Leshan, Leshan 614000, China
关键词:
3D打印前列腺增生症绿激光前列腺汽化术
Keywords:
3D printingLaser working shealthPhotoselective vaporization of the prostate
文献标志码:
A
摘要:
目的探讨3D打印制作激光工作鞘在经尿道绿激光前列腺汽化术中的安全性和有效性。方法选择2019年9~11月50例前列腺增生,前列腺体积25~75 ml,平均45 ml,采用3D打印制作的激光工作鞘连接F21膀胱镜外鞘行经尿道绿激光前列腺汽化术。结果50例手术均成功完成,手术时间30~95 min,平均56 min,术中出血<50 ml。术后膀胱冲洗时间8~36 h,平均17 h。术后2~4天拔除尿管,无尿外渗、尿失禁、排尿困难。术后6个月国际前列腺症状评分(International Prostate Symptom Score,IPSS)由术前(23.5±4.7)分降至(4.7±1.6)分(t=28.506,P=0.000),最大尿流率(Qmax)由术前(6.3±3.3)ml/s提高至(21.7±4.7)ml/s(t=-20.754,P=0.000),均无尿道狭窄、排尿困难、逆行射精、膀胱颈挛缩等发生。结论3D打印制作激光工作鞘连接F21膀胱镜外鞘的绿激光前列腺汽化术治疗前列腺增生微创、安全、有效。
Abstract:
ObjectiveTo evaluate the safety and efficacy of 3Dprinted laser working shealth applying in the photoselective vaporization of the prostate (PVP).MethodsFrom September 2019 to November 2019, 50 cases of benign prostate hyperplasia (BPH) were prospectively collected. The volume of the prostate was 25-75 ml (mean, 45 ml). PVP was performed using a 3Dprinted laser working sheath which connected with the outer sheath of F21 cystoscope.ResultsAll the 50 cases of BPH were effectively treated with PVP in the mean time of 56 minutes (range, 30-95 minutes). The intraoperative blood loss was <50 ml. The mean postoperative bladder irrigation time was 17 hours (range, 8-36 hours). The urethral catheter was withdrawn at 2-4 days. No urinary infiltration or incontinence occurred. All the cases on reexamination after 6 months showed that significantly decreased International Prostate Symptom Score (IPSS) (from 23.5±4.7 to 4.7±1.6, t=28.506, P=0.000) and increased Qmax (from 63±3.3 ml/s to 21.7±4.7 ml/s, t=-20.754, P=0.000). No patients had urinary stricture, dysurine, retrograde ejaculation, and bladder neck contracture.Conclusion3Dprinted laser working shealth connecting with the outer sheath of F21 cystoscope is safe, effective and minimally invasive for the treatment of BPH.

参考文献/References:

[1]Zhang J,Wang X, Zhang Y,et al.1470 nm diode laser enucleation vs plasmakinetic resection of the prostate for benign prostatic hyperplasia:a randomized study.J Endourol,2019,33(3):211-217.
[2]Tasc AI,llbey YO,Tugcu V,et al.Transurethral resection of the prostate with monopolar resectoscope:singlesurgeon experience and longterm results of after 3589 procedures.Urology,2011,78(5):1151-1155.
[3]Altay B,Erkurt B,Kiremit MC,et al.180W XPS GreenLight laser vaporization for benign prostate hyperplasia:12month safety and efficacy results for glands larger than 80 mL.Lasers Med Sci,2015,30(1):317-323.
[4]刘南,罗宏,周宏,等.经尿道手术治疗小体积前列腺增生所致膀胱出口梗阻.中国微创外科杂志,2012,12(3):242-244.
[5]Mayer EK,Kroeze SG,Chopra S,et al.Examining the ‘gold standard’:a comparative critical analysis of three consecutive decades of monopolar transurethral resection of the prostate (TURP) outcomes.BJU Int,2012,110(11):1595-1601.
[6]马贵斌,李立宇,陶志兴,等.去除外鞘电切术在治疗良性前列腺增生中的应用.中华泌尿外科杂志,2013,34(5):396.
[7]曹贵华,杜建平,黄贵闽,等.F19.8膀胱镜联合膀胱超微造瘘在经尿道绿激光前列腺汽化术中的应用.中华男科学杂志,2018,24(12):1150-1151.
[8]曹健,朱帅,叶明佶,等.3D打印技术辅助腹腔镜下肾肿瘤冷冻消融术.中国微创外科杂志,2018,18(12):1118-1120.
[9]冯德宏,刘仪,王凌,等.3D打印臼杯-垫块复合假体在髋关节翻修术中的应用六例报告.中国骨与关节杂志,2020,9(2):129-134.
[10]王江平,焦勇,许志斌,等.腹腔镜3D打印血管外支架植入术治疗胡桃夹综合征的安全性和有效性.中华泌尿外科杂志,2018,39(3):200-204.

备注/Memo

备注/Memo:
基金项目:四川省医学会课题(S18045)**通讯作者,Email:cgh75@sina.com
更新日期/Last Update: 2021-01-13