[1]姚优修 综述 孟秀丽* 审校.全机器人不停跳冠状动脉旁路移植术的麻醉管理进展[J].中国微创外科杂志,2015,15(8):744-748.
 Yao Youxiu,Meng Xiuli..Progress of Anesthetic Management of Robotic Totally Endoscopic Coronary Artery Bypass on Beating Heart[J].Chinese Journal of Minimally Invasive Surgery,2015,15(8):744-748.
点击复制

全机器人不停跳冠状动脉旁路移植术的麻醉管理进展()
分享到:

《中国微创外科杂志》[ISSN:1009-6604/CN:11-4526/R]

卷:
15
期数:
2015年8期
页码:
744-748
栏目:
文献综述
出版日期:
2015-08-20

文章信息/Info

Title:
Progress of Anesthetic Management of Robotic Totally Endoscopic Coronary Artery Bypass on Beating Heart
作者:
姚优修 综述 孟秀丽* 审校
(北京大学第三医院麻醉科,北京100191)
Author(s):
Yao Youxiu Meng Xiuli.
Department of Anesthesiology, Peking University Third Hospital, Beijing 100191, China
关键词:
不停跳冠状动脉旁路移植术机器人单肺通气加压CO2气胸麻醉
Keywords:
Offpump coronary artery bypass graftingRobotUnilateral lung ventilationPressured pneumothoraxAnesthesia
分类号:
R614.1
文献标志码:
A
摘要:
全机器人不停跳冠状动脉旁路移植术创伤小,术后恢复快,是未来微创冠状动脉外科的趋势,对麻醉管理提出更高的要求,主要包括加压CO2气胸、单肺通气的应用、经食道超声心动图的监测、术中血流动力学的维持、体外循环及中转开胸手术的准备、室颤的处理等,要求麻醉医师对患者病理生理的调控及围术期的管理达到更精细化。
Abstract:
Robotic totally endoscopic coronary artery bypass on beating heart (BHTECAB), a minimally invasive surgical approach with rapid postoperative recovery, is becoming the future trend of minimally invasive coronary surgery, which demands a higher standard for anesthetic management. It comprises pressured pneumothorax, unilateral lung ventilation, transesophageal echocardiography monitoring, hemodynamics maintaining, preparation for cardiopulmonary bypass and conversion to sternotomy, and ventricular fibrillation treatment, which require anesthesiologists to achieve more refined perioperative management and pathophysiological regulation.

参考文献/References:

[1]Deshpande SP, Lehr E, Odonkor P, et al. Anesthetic management of robotically assisted totally endoscopic coronary artery bypass surgery (TECAB). J Cardiothorac Vasc Anesth, 2013, 27(3): 586-599.
[2]杨明,高长青.机器人心脏手术的应用现状.中国微创外科杂志,2012,12(7):586-589.
[3]Jansens JL. Beating heart totally endoscopic coronary artery bypass. Multimed Man Cardiothorac Surg, 2011,2011(914): mmcts.2010.004663.
[4]Cheng N, Gao C, Yang M, et al. Analysis of the learning curve for beating heart, totally endoscopic, coronary artery bypass grafting. J Thorac Cardiovasc Surg,2014, 148(5): 1832-1836.
[5]Wehman B, Lehr EJ, Lahiji K,et al. Patient anatomy predicts operative time in robotic totally endoscopic coronary artery bypass surgery. Interact Cardiovasc Thorac Surg,2014, 19(4): 572-576.
[6]Wiedemann D, Bonaros N, Schachner T, et al. Surgical problems and complex procedures: issues for operative time in robotic totally endoscopic coronary artery bypass grafting. J Thorac Cardiovasc Surg,2012, 143(3): 639-647.
[7]Khalil MA, Abdel Azeem MS. The impact of dexmedetomidine infusion in sparing morphine consumption in offpump coronary artery bypass grafting. Semin Cardiothorac Vasc Anesth, 2013,17(1): 66-71.
[8]Bakhtiary F, Therapidis P, Dzemali O, et al. Impact of high thoracic epidural anesthesia on incidence of perioperative atrial fibrillation in offpump coronary bypass grafting: a prospective randomized study. J Thorac Cardiovasc Surg, 2007, 134(2): 460-464.
[9]Horlocker TT, Wedel DJ, Rowlingson JC, et al. Regional anesthesia in the patient receiving antithrombotic or thrombolytic therapy: American Society of Regional Anesthesia and Pain Medicine EvidenceBased Guidelines (Third Edition). Reg Anesth Pain Med,2010,35(1): 64-101.
[10]Porat E, Sharony R, Ivry S, et al. Hemodynamic changes and right heart support during vertical displacement of the beating heart. Ann Thorac Surg,2000,69(4): 1188-1191.
[11]Chassot PG, van der Linden P, Zaugg M, et al.Offpump coronary artery bypass surgery: physiology and anaesthetic management. Br J Anaesth,2004, 92(3): 400-413.
[12]Ender J, Brodowsky M, Falk V, et al. Highfrequency jet ventilation as an alternative method compared to conventional onelung ventilation using doublelumen tubes during minimally invasive coronary artery bypass graft surgery. J Cardiothorac Vasc Anesth,2010,24(4): 602-607.
[13]Byhahn C, Mierdl S, Meininger D, et al. Hemodynamics and gas exchange during carbon dioxide insufflation for totally endoscopic coronary artery bypass grafting. Ann Thorac Surg, 2001,71(5): 1496-1501.
[14]Vassiliades TA Jr. The cardiopulmonary effects of singlelung ventilation and carbon dioxide insufflation during thoracoscopic internal mammary artery harvesting. Heart Surg Forum, 2002, 5(1): 22-24.
[15]Karzai W, Schwarzkopf K. Hypoxemia during onelung ventilation: prediction, prevention, and t reatment. Anesthesiology,2009, 110(6): 1402-1411.
[16]Rothen HU, Sporre B, Engberg G, et al. Prevention of atelectasis during general anaesthesia. Lancet,1995,345(8962): 1387-1391.
[17]Kapoor PM, Chowdhury U, Mandal B, et al. Transesophageal echocardiography in offpump coronary artery bypass grafting. Ann Card Anaesth, 2009,12(2): 167.
[18]Mierdl S, Byhahn C, Lischke V, et al. Segmental myocardial wall motion during minimally invasive coronary artery bypass grafting using open and endoscopic surgical techniques. Anesth Analg,2005, 100(2): 306-314.
[19]Moises VA, Mesquita CB, Campos O, et al. Importance of intraoperative transesophageal echocardiography during coronary artery surgery without cardiopulmonary bypass. J Am Soc Echocardiogr,1998,11(12): 1139-1144.
[20]Hatton KW, Kilinski LC, Ramaiah C, et al. Multiple failed external defibrillation attempts during robotassisted internal mammary harvest for myocardial revascularization. Anesth Analg,2006, 103(5): 1113-1114.
[21]Schachner T, Bonaros N, Wiedemann D, et al. Predictors, causes, and consequences of conversions in robotically enhanced totally endoscopic coronary artery bypass graft surgery. Ann Thorac Surg,2011, 91(3): 647-653.
[22]Srivastava S, Gadasalli S, Agusala M, et al. Beating heart totally endoscopic coronary artery bypass.Ann Thorac Surg,2010, 89(6): 1873-1879.
[23]Gao C, Yang M, Wu Y, et al. Early and midterm results of totally endoscopic coronary artery bypass grafting on the beating heart. J Thorac Cardiovasc Surg, 2011, 142(4): 843-849.
[24]Srivastava S, Barrera R, Quismundo S. One hundred sixtyfour consecutive beating heart totally endoscopic coronary artery bypass cases without intraoperative conversion. Ann Thorac Surg, 2012, 94(5): 1463-1468.
[25]Seco M, Edelman JJ, Yan TD, et al. Systematic review of roboticassisted, totally endoscopic coronary artery bypass grafting. Ann Cardiothorac Surg,2013, 2(4): 408-418.
[26]Bonaros N, Schachner T, Wiedemann D, et al. Quality of life improvement after robotically assisted coronary artery bypass grafting. Cardiology,2009, 114(1): 59-66.
[27]Wiedemann D, Schachner T, Bonaros N, et al. Robotic totally endoscopic coronary artery bypass grafting in men and women: are there sex differences in outcome? Ann Thorac Surg, 2013, 96(5): 1643-1647.
[28]Zaouter C, Imbault J, Labrousse L, et al. Association of Robotic Totally Endoscopic Coronary Artery Bypass Graft Surgery Associated With a Preliminary Cardiac Enhanced Recovery After Surgery Program: A Retrospective Analysis. J Cardiothorac Vasc Anesth, 2015, Mar 5.pii:S1053-0770(15)00129-9.[Epub ahead of print]
[29]Balkhy HH, Wann LS, Krienbring D, et al. Integrating coronary anastomotic connectors and robotics toward a totally endoscopic beating heart approach: review of 120 cases. Ann Thorac Surg, 2011, 92(3): 821-827.
[30]Gibber M, Lehr EJ, Kon ZN, et al. Is there a role for robotic totally endoscopic coronary artery bypass in patients with a colostomy? Innovations (Phila),2014, 9(6): 448-450.
[31]Deshpande SP, Fitzpatrick M, Lehr EJ . Totally endoscopic robotic coronary artery bypass surgery. Curr Opin Anaesthesiol,2014,27(1): 49-56.

备注/Memo

备注/Memo:
*通讯作者,Email: meng_xiuli@163.com
更新日期/Last Update: 2016-01-04